How to start a simulation with TACITE

 
 

            In any case one need 9 user defined files in the standart directory to start TACITE computation. Firstly one define the simulation generic name .
            We use SimName as the example generic name.

            These files are :
 

           SimName   : Specifies to tacite code the simulation generic name, SimName.* files, and inculdes some comment lines from user.

        SimName.GEO  : Describe flow device and equipements such as valves or pumps dimensions and metric caracteristics.

        SimName.TOP : Define the topological survey of the flow device in term of cumulative lengh and absolute elevation.

        SimName.MSH : Define the discretization of the flow device as a function of cumulative length.

        SimName.PVT : Contain thermodynamic properties of the fluids.

        SimName.SCE : Define the time dependant scenario. That is the boundaries conditions and characteristics of the operations
         that cause transient flow.

        SimName.THE : Contain the thermal properties of the flow device like temperature and insulation.

        SimName.STO : Define the results storage specifications : Frequency and type. Set the type to ASCII to operate data structure
         modification to allow post processing and visualization.

        TACITE.JOB :This file is almost a clone of the SimName file.
 

             One might check the compatibility between files before start a run. In any case TACITE will return errors messages
 
 

TOP