The results files


Binary or ASCII files as specified in SimName.STO file.

SimName_#.XV : Store only space dependent variable i.e. the topology  and section area distributuion.
SimName_#.XN : organization and nomenclature of SimName_#.XV file.
SimName_#.TV : Store only the time dependent variables
SimName_#.TN : organization and nomenclature of SimName_#.TV  file.
SimName_#.TXV : Store  the space-time dependent variables
SimName_#.TXN : organization and nomenclature of SimName_#.TV  file.

These programs order the variables in columns. This type of file is viewable with a plotter like xmgr.

Space dependant variables : Structure of the SimName_#.XV file

*International system unit
 
Cumulative Location
Absolute Elevation
Cross section area
X1
elev1
A1
X2
elev2
A2
...
...
...
pipe length
elevN
AN

Time dependant variables : Structure of the SimName_#.TV file

*International system unit
 
Time
(0<T<Tk)
Cumulative produced gas mass
Cumulative produced liquid mass
Total gas volume
Total liquid volume
Total gas mass
Total liquid mass
Total mass of component 1
Total mass of component i     (1<i< n)
.............
Total mass of component n
0
                 
T1
                 
...
                 
Tk
                 

Time-Space dependant variables : Structure of the SimName_#.TXV file

*International system unit
 
 
Time
(0<T<Tk)
Abscice
(0<X<XN)
Flow patern
Slug fraction
Pressure
Temperature
Gas volumetric fraction
Liquid volumetric fraction
Superficial gas velocity
Superficial liquid velocity
Gas mass flow rate
Liquid mass flow rate
Mass flow rate of comp 1
Mass fraction of comp 1 in gas
Mass fraction of comp 1 in liquid
 Mass flow rate of comp i
..........
 Mass fraction of comp i in gas
.............
Mass fraction of comp i in gas 
............
 .......
 Mass fraction of comp n in gas
0
 X1
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 0
 ...
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 0
 XN
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 ...
... 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Tk
X1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Tk
 ...
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Tk
 XN
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

    Sometimes TACITE does an automatic refinement of the mesh. The number of cells may also be different of user's specification. Read at the end of the SimName_#.REP file the number of effective cells.
 

TOP