The results files
Binary or ASCII files as specified in SimName.STO file.SimName_#.XV : Store only space dependent variable i.e. the topology and section area distributuion.
SimName_#.XN : organization and nomenclature of SimName_#.XV file.
SimName_#.TV : Store only the time dependent variables
SimName_#.TN : organization and nomenclature of SimName_#.TV file.
SimName_#.TXV : Store the space-time dependent variables
SimName_#.TXN : organization and nomenclature of SimName_#.TV file.These programs order the variables in columns. This type of file is viewable with a plotter like xmgr.
Space dependant variables : Structure of the SimName_#.XV file*International system unit
Cumulative Location Absolute Elevation Cross section area X1 elev1 A1 X2 elev2 A2 ... ... ... pipe length elevN AN Time dependant variables : Structure of the SimName_#.TV file
*International system unit
Time
(0<T<Tk)Cumulative produced gas mass Cumulative produced liquid mass Total gas volume Total liquid volume Total gas mass Total liquid mass Total mass of component 1 Total mass of component i (1<i< n)
.............Total mass of component n 0 T1 ... Tk Time-Space dependant variables : Structure of the SimName_#.TXV file
*International system unit
Time
(0<T<Tk)Abscice
(0<X<XN)Flow patern Slug fraction Pressure Temperature Gas volumetric fraction Liquid volumetric fraction Superficial gas velocity Superficial liquid velocity Gas mass flow rate Liquid mass flow rate Mass flow rate of comp 1 Mass fraction of comp 1 in gas Mass fraction of comp 1 in liquid Mass flow rate of comp i
..........Mass fraction of comp i in gas
.............Mass fraction of comp i in gas
................... Mass fraction of comp n in gas 0 X1 0 ... 0 XN ... ... Tk X1 Tk ... Tk XN
Sometimes TACITE does an automatic refinement of the mesh. The number of cells may also be different of user's specification. Read at the end of the SimName_#.REP file the number of effective cells.